Cisco ASA / FTD Syslog 105021: (Failover_unit) Standby unit failed to sync due to a locked
Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 105021
Severity 1 — Alert
Message format
%ASA-1-105021: (Failover_unit) Standby unit failed to sync due to a lockedExplanation
During configuration synchronization, a standby unit will reload itself if some other process locks the configuration for more than five minutes, which prevents the failover process from applying the new configuration. This can occur when an administrator pages through a running configuration on the standby unit while configuration synchronization is in process. See also the show running-config command in privileged EXEC mode and the pager lines num command in global configuration mode in the Command Reference Guides.
Recommended action
No recommended action was captured in this dataset. Consult the Cisco documentation for this message and your software version.
Cisco FTD message 105021
Severity 1 — Alert
Message format
%FTD-1-105021: (Failover_unit) Standby unit failed to sync due to a lockedExplanation
During configuration synchronization, a standby unit will reload itself if some other process locks the configuration for more than five minutes, which prevents the failover process from applying the new configuration. This can occur when an administrator pages through a running configuration on the standby unit while configuration synchronization is in process. See also the show running-config command in privileged EXEC mode and the pager lines num command in global configuration mode in the Command Reference Guides.
Recommended action
Avoid viewing or modifying the configuration on the standby unit when it first boots up and is in the process of establishing a failover connection with the active unit.
Search another message · Browse this range
Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.