Cisco ASA Syslog 105508: (Primary|Secondary) Error creating failover connection socket
Reference for ASA firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 105508
Severity 2 — Critical
Message format
%ASA-2-105508: (Primary|Secondary) Error creating failover connection socketExplanation
An internal error occurred while attempting to create a socket on the Active unit for exchanging failover control messages with the Backup unit.
Plain-English interpretation
The Active ASA failed to create a socket for failover heartbeat and state synchronization with the Backup unit, indicating a system-level resource exhaustion or kernel networking issue. This is a downstream consequence of an earlier failover connection failure (104509/104510) and requires investigation of system resources, interface connectivity, and preceding error messages to identify root cause.
Recommended action
This message is preceeded by a 104509 or 104510 message. Follow the
Illustrative example
Illustration; not a captured production log.
Primary Error creating failover connection socket on interface GigabitEthernet0/0 (10.0.0.1) attempting to reach Secondary at 10.0.0.2:20000The Active ASA at 10.0.0.1 was unable to establish the failover control socket to the Backup unit at 10.0.0.2 over the dedicated failover interface GigabitEthernet0/0, preventing normal heartbeat and configuration synchronization; check the preceding 104509/104510 messages and verify interface connectivity, IP configuration, and system memory availability.
Related failover messages
- 101001 — (Primary) Failover cable OK. (ASA / FTD)
- 101002 — (Primary) Bad failover cable. (ASA / FTD)
- 101005 — (Primary) Error reading failover cable status. (ASA / FTD)
- 105001 — (Primary) Disabling failover. (ASA / FTD)
- 105002 — (Primary) Enabling failover. (ASA / FTD)
Search another message · Browse this range
Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.