Cisco ASA / FTD Syslog 210003: Unknown LU Object number
Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 210003
Severity 3 — Error
Message format
%ASA-3-210003: Unknown LU Object numberExplanation
Stateful Failover received an unsupported Logical Update object and was unable to process it. This can be caused by corrupted memory, LAN transmissions, and other events.
Recommended action
If you see this error infrequently, then no action is required. If this error occurs frequently, check the Stateful Failover link LAN connection. If the error was not caused by a faulty failover link LAN connection, determine if an external user is trying to compromise the protected network. Also check for misconfigured clients.
Cisco FTD message 210003
Severity 3 — Error
Message format
%FTD-3-210003: Unknown LU Object numberExplanation
Stateful Failover received an unsupported Logical Update object and was unable to process it. This can be caused by corrupted memory, LAN transmissions, and other events.
Recommended action
If you see this error infrequently, then no action is required. If this error occurs frequently, check the Stateful Failover link LAN connection. If the error was not caused by a faulty failover link LAN connection, determine if an external user is trying to compromise the protected network. Also check for misconfigured clients.
Search another message · Browse this range
Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.