Cisco ASA / FTD Syslog 210003: Unknown LU Object number

Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.

Cisco ASA message 210003

Severity 3 — Error

Message format

%ASA-3-210003: Unknown LU Object number

Explanation

Stateful Failover received an unsupported Logical Update object and was unable to process it. This can be caused by corrupted memory, LAN transmissions, and other events.

Recommended action

If you see this error infrequently, then no action is required. If this error occurs frequently, check the Stateful Failover link LAN connection. If the error was not caused by a faulty failover link LAN connection, determine if an external user is trying to compromise the protected network. Also check for misconfigured clients.

Cisco ASA documentation

Cisco FTD message 210003

Severity 3 — Error

Message format

%FTD-3-210003: Unknown LU Object number

Explanation

Stateful Failover received an unsupported Logical Update object and was unable to process it. This can be caused by corrupted memory, LAN transmissions, and other events.

Recommended action

If you see this error infrequently, then no action is required. If this error occurs frequently, check the Stateful Failover link LAN connection. If the error was not caused by a faulty failover link LAN connection, determine if an external user is trying to compromise the protected network. Also check for misconfigured clients.

Cisco FTD documentation

← Previous: 210002Next: 210005 →

Search another message · Browse this range

Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.