Cisco ASA / FTD Syslog 212005: incoming SNMP request (number bytes) from interface_name exceeds

Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.

Cisco ASA message 212005

Severity 3 — Error

Message format

%ASA-3-212005: incoming SNMP request (number bytes) from interface_name exceeds

Explanation

The length of the incoming SNMP request that is destined for the Secure Firewall ASA exceeds the size of the internal data buffer (512 bytes) used for storing the request during internal processing. The Secure Firewall ASA is unable to process this request. The SNMP traffic passing through the Secure Firewall ASA on any interface is not affected.

Recommended action

No recommended action was captured in this dataset. Consult the Cisco documentation for this message and your software version.

Cisco ASA documentation

Cisco FTD message 212005

Severity 3 — Error

Message format

%FTD-3-212005: incoming SNMP request (number bytes) from interface_name exceeds

Explanation

The length of the incoming SNMP request that is destined for the Secure Firewall Threat Defense device exceeds the size of the internal data buffer (512 bytes) used for storing the request during internal processing. The Secure Firewall Threat Defense device is unable to process this request. The SNMP traffic passing through the Secure Firewall Threat Defense device on any interface is not affected.

Recommended action

Have the SNMP management station resend the request with a shorter length. For example, instead of querying multiple MIB variables in one request, try querying only one MIB variable in a request. You may need to modify the configuration of the SNMP manager software.

Cisco FTD documentation

← Previous: 212004Next: 212006 →

Search another message · Browse this range

Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.