Cisco ASA / FTD Syslog 212011: engineBoots is set to maximum value. Reason: Reason. User
Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 212011
Severity 3 — Error
Message format
%ASA-3-212011: engineBoots is set to maximum value. Reason: Reason. UserExplanation
The device has rebooted 214783647 times, which is the maximum allowed value of the engineBoots variable, or an error reading the persistent value from flash memory has occurred. The engineBoots value is stored in flash memory in the flash:/snmp/ctx-name file, where ctx-name is the name of the context. In single mode, the name of this file is flash:/snmp/single_vf. In multi-mode, the name of the file for the admin context is flash:/snmp/admin. During a reboot, if the device is unable to read from the file or write to the file, the engineBoots value is set to the maximum. • %s—A string that represents the reason that the engineBoots value is set to the maximum allowed value. The two valid strings are “device reboots” and “error accessing persistent data.”
Recommended action
For the first string, the administrator must delete all SNMP Version 3 users and add them again to reset the engineBoots variable to 1. All subsequent Version 3 queries will fail until all users have been removed. For the second string, the administrator must delete the context-specific file, then delete all SNMP Version users, and add them again to reset the engineBoots variable to 1. All subsequent Version 3 queries will fail until all users have been removed.
Cisco FTD message 212011
Severity 3 — Error
Message format
%FTD-3-212011: engineBoots is set to maximum value. Reason: Reason. UserExplanation
The device has rebooted 214783647 times, which is the maximum allowed value of the engineBoots variable, or an error reading the persistent value from flash memory has occurred. The engineBoots value is stored in flash memory in the flash:/snmp/ctx-name file, where ctx-name is the name of the context. In single mode, the name of this file is flash:/snmp/single_vf. In multi-mode, the name of the file for the admin context is flash:/snmp/admin. During a reboot, if the device is unable to read from the file or write to the file, the engineBoots value is set to the maximum. • %s—A string that represents the reason that the engineBoots value is set to the maximum allowed value. The two valid strings are “device reboots” and “error accessing persistent data.”
Recommended action
For the first string, the administrator must delete all SNMP Version 3 users and add them again to reset the engineBoots variable to 1. All subsequent Version 3 queries will fail until all users have been removed. For the second string, the administrator must delete the context-specific file, then delete all SNMP Version users, and add them again to reset the engineBoots variable to 1. All subsequent Version 3 queries will fail until all users have been removed.
Search another message · Browse this range
Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.