Cisco ASA / FTD Syslog 402127: CRYPTO: The platform is skipping the writing of latest Crypto

Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.

Cisco ASA message 402127

Severity 4 — Warning

Message format

%ASA-4-402127: CRYPTO: The platform is skipping the writing of latest Crypto

Explanation

A functional problem with the hardware crypto chip was detected (see messages 4402124 and 4402125). This message indicates a crypto archive file was not written, because the maximum number of crypto archive files already existed. • max_number >— Maximum number of files allowed in the archive directory; currently set to two • >archive_directory— Name of the archive directory

Recommended action

Forward previously generated crypto archive files to the Cisco TAC. Remove the previously generated archive file(s) so that more can be written (if deemed necessary).

Cisco ASA documentation

Cisco FTD message 402127

Severity 4 — Warning

Message format

%FTD-4-402127: CRYPTO: The platform is skipping the writing of latest Crypto

Explanation

A functional problem with the hardware crypto chip was detected (see messages 4402124 and 4402125). This message indicates a crypto archive file was not written, because the maximum number of crypto archive files already existed. • max_number >— Maximum number of files allowed in the archive directory; currently set to two • >archive_directory— Name of the archive directory

Recommended action

Forward previously generated crypto archive files to the Cisco TAC. Remove the previously generated archive file(s) so that more can be written (if deemed necessary).

Cisco FTD documentation

← Previous: 402126Next: 402128 →

Search another message · Browse this range