Cisco ASA Syslog 403103: PPP virtual interface max connections reached

Reference for ASA firewall logs. Check the source documentation against your installed software version.

Cisco ASA message 403103

Severity 4 — Warning

Message format

%ASA-4-403103: PPP virtual interface max connections reached

Explanation

The module cannot accept additional PPTP connections.Connections are allocated as soon as they are available.

Plain-English interpretation

The ASA has reached its configured maximum number of concurrent PPTP connections on a virtual interface and cannot accept new connection attempts until existing sessions terminate. This is a resource exhaustion condition on the PPP subsystem, not a configuration error. Existing connections continue normally; only new inbound PPTP sessions will be rejected until capacity is available.

Recommended action

None required.

Illustrative example

Illustration; not a captured production log.

Jan 15 14:23:47 asa-01 %ASA-4-403103: PPP virtual interface max connections reached

The ASA PPP virtual interface hit its connection limit and rejected a new PPTP session attempt; all available connection slots on the PPP interface are currently occupied by active sessions.

Cisco ASA documentation

← Previous: 403102Next: 403104 →

Search another message · Browse this range