Cisco ASA Syslog 413008: An unsupported configuration is detected.
Reference for ASA firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 413008
Severity 1 — Alert
Message format
%ASA-1-413008: An unsupported configuration is detected.Explanation
Only one power supply and one fan module are inserted when an ASA 10G SSP and IPS 10G SSP are present.
Plain-English interpretation
The ASA has detected a power supply and cooling configuration mismatch on a chassis with both ASA 10G SSP and IPS 10G SSP modules installed. These dual high-performance modules require redundant power supplies (two PSUs) rather than a single PSU paired with a fan module; the current configuration lacks sufficient power delivery capacity and thermal management for both modules to operate reliably.
Recommended action
When using an ASA 10G SSP and IPS 10G SSP, insert two power supplies instead of one fan module and one power supply module.
Illustrative example
Illustration; not a captured production log.
%ASA-1-413008: An unsupported configuration is detected. Detected configuration: 1 power supply and 1 fan module with ASA 10G SSP and IPS 10G SSP present on chassis SN:JMX2249A1234.The ASA detected that it has only one power supply and one fan module installed while running both ASA 10G SSP and IPS 10G SSP modules, which is an unsupported configuration. The administrator must install a second power supply to replace the fan module to meet the redundancy and power requirements of this dual-module setup.