Cisco ASA Syslog 420006: Virtual sensor not present and fail-close mode used, dropping
Reference for ASA firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 420006
Severity 3 — Error
Message format
%ASA-3-420006: Virtual sensor not present and fail-close mode used, droppingExplanation
Packets are dropped when the IPS fail-close mode is used, and the virtual sensor used for the packet is not present. • protocol— Protocol used to send the packet • ifc_in —Input interface name • ifc_out —Output interface name • SIP —Source IP address of the packet • SPORT —Source port of the packet • DIP —Destination IP address of the packet • DPORT —Destination port of the packet
Plain-English interpretation
The ASA's IPS engine attempted to inspect a packet but the assigned virtual sensor configuration is missing or unavailable, and the device is configured to fail-close (drop traffic when inspection fails). This typically occurs after sensor configuration changes, incomplete deployments, or when a referenced sensor has been deleted without updating the policy.
Recommended action
Add the virtual sensor.
Illustrative example
Illustration; not a captured production log.
2024-01-15T14:32:47.123Z ASA [420006] protocol=tcp ifc_in=outside ifc_out=inside SIP=203.0.113.45 SPORT=54321 DIP=10.1.2.50 DPORT=443 Virtual sensor not present and fail-close mode used, droppingA TCP packet from external host 203.0.113.45:54321 destined for internal host 10.1.2.50:443 (HTTPS) was dropped on the inside interface because the IPS virtual sensor assigned to that traffic policy is missing, and fail-close mode prevented the packet from passing uninspected.
Search another message · Browse this range
Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.