Cisco ASA / FTD Syslog 434001: SFR card not up and fail-close mode used, dropping protocol
Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 434001
Severity 4 — Warning
Message format
%ASA-4-434001: SFR card not up and fail-close mode used, dropping protocolExplanation
A packet has been dropped because of a fail-close configuration for the module. Your loss of connectivity for all the flows is caused by redirecting them to the module, because the fail-close configuration is designed to drop all the flows if the module is down.
Recommended action
Try to understand the reason for failure and restore services. Alternatively, you can use the fail-open option even if the card does not recover immediately. Note that in the fail-open configuration, all packets to the module are bypassed if the card status is down.
Cisco FTD message 434001
Severity 4 — Warning
Message format
%FTD-4-434001: SFR card not up and fail-close mode used, dropping protocolExplanation
A packet has been dropped because of a fail-close configuration for the module. Your loss of connectivity for all the flows is caused by redirecting them to the module, because the fail-close configuration is designed to drop all the flows if the module is down.
Recommended action
Try to understand the reason for failure and restore services. Alternatively, you can use the fail-open option even if the card does not recover immediately. Note that in the fail-open configuration, all packets to the module are bypassed if the card status is down.