Cisco ASA / FTD Syslog 507003: protocol flow from originating_interface:src_ip/src_port to
Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 507003
Severity 3 — Error
Message format
%ASA-3-507003: protocol flow from originating_interface:src_ip/src_port toExplanation
The TCP proxy or session API terminated a connection for various reasons, which are provided in the message. • protocol—The protocol for the flow • src_ip—The source IP address for the flow • src_port —The name of the source port for the flow • dest_if —The destination interface for the flow • dest_ip —The destination IP address for the flow • dest_port —The destination port for the flow • reason —The description of why the flow is being terminated by the inspection engine. Valid reasons include: - Failed to create flow - Failed to initialize session API - Filter rules installed/matched are incompatible - Failed to consolidate new buffer data with original - Reset unconditionally - Reset based on “service reset inbound” configuration - Disconnected, dropped packet - Packet length changed - Reset reflected back to sender - Proxy inspector reset unconditionally - Proxy inspector drop reset - Proxy inspector received data after FIN - Proxy inspector disconnected, dropped packet - Inspector reset unconditionally - Inspector drop reset - Inspector received data after FIN - Inspector disconnected, dropped packet - Could not buffer unprocessed data
Recommended action
No recommended action was captured in this dataset. Consult the Cisco documentation for this message and your software version.
Cisco FTD message 507003
Severity 3 — Error
Message format
%FTD-3-507003: protocol flow from originating_interface:src_ip/src_port toExplanation
The TCP proxy or session API terminated a connection for various reasons, which are provided in the message. • protocol—The protocol for the flow • src_ip—The source IP address for the flow • src_port —The name of the source port for the flow • dest_if —The destination interface for the flow • dest_ip —The destination IP address for the flow • dest_port —The destination port for the flow • reason —The description of why the flow is being terminated by the inspection engine. Valid reasons include: - Failed to create flow - Failed to initialize session API - Filter rules installed/matched are incompatible - Failed to consolidate new buffer data with original - Reset unconditionally - Reset based on “service reset inbound” configuration - Disconnected, dropped packet - Packet length changed - Reset reflected back to sender - Proxy inspector reset unconditionally - Proxy inspector drop reset - Proxy inspector received data after FIN - Proxy inspector disconnected, dropped packet - Inspector reset unconditionally - Inspector drop reset - Inspector received data after FIN - Inspector disconnected, dropped packet - Could not buffer unprocessed data
Recommended action
No recommended action was captured in this dataset. Consult the Cisco documentation for this message and your software version.