Cisco ASA / FTD Syslog 735006: Power Supply Unit Redundancy Lost
Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 735006
Severity 1 — Alert
Message format
%ASA-1-735006: Power Supply Unit Redundancy LostExplanation
A power supply failure occurred. Power supply unit redundancy has been lost, but the Secure Firewall ASA is functioning normally with minimum resources. Any further failures will result in an Secure Firewall ASA shutdown.
Recommended action
To regain full redundancy, perform the following steps: 1. Check for AC power failure. 2. Replace the power supply. 3. If the problem persists, record the message as it appears and contact the Cisco TAC.
Cisco FTD message 735006
Severity 1 — Alert
Message format
%FTD-1-735006: Power Supply Unit Redundancy LostExplanation
A power supply failure occurred. Power supply unit redundancy has been lost, but the Secure Firewall Threat Defense device is functioning normally with minimum resources. Any further failures will result in an Secure Firewall Threat Defense device shutdown.
Recommended action
To regain full redundancy, perform the following steps: 1. Check for AC power failure. 2. Replace the power supply. 3. If the problem persists, record the message as it appears and contact the Cisco TAC.