Cisco ASA / FTD Syslog 735028: ASA was previously shutdown due to a CPU Voltage Regulator
Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 735028
Severity 2 — Critical
Message format
%ASA-2-735028: ASA was previously shutdown due to a CPU Voltage RegulatorExplanation
At boot time, the Secure Firewall ASA detected a shutdown that occurred because of a CPU voltage regulator running beyond the maximum safe operating temperature. Enter the show environment command to indicate that this event has occurred.
Recommended action
The chassis and CPU need to be inspected immediately for ventilation issues.
Cisco FTD message 735028
Severity 2 — Critical
Message format
%FTD-2-735028: FTD was previously shutdown due to a CPU Voltage RegulatorExplanation
At boot time, the Secure Firewall Threat Defense device detected a shutdown that occurred because of a CPU voltage regulator running beyond the maximum safe operating temperature. Enter the show environment command to indicate that this event has occurred.
Recommended action
The chassis and CPU need to be inspected immediately for ventilation issues.
Search another message · Browse this range
Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.