Cisco ASA / FTD Syslog 748002: Clustering configuration on the chassis is missing or incomplete;

Reference for ASA / FTD firewall logs. Check the source documentation against your installed software version.

Cisco ASA message 748002

Severity 4 — Warning

Message format

%ASA-4-748002: Clustering configuration on the chassis is missing or incomplete;

Explanation

Configurations are missing or incomplete in the MIO (for example, a cluster group is not configured, or a cluster control link is not configured). • slot_number —The blade slot ID within the chassis • chassis_number —The chassis ID, which is unique for each chassis

Recommended action

Go to the MIO console and configure the cluster service type, add the module to the service type, and define the cluster control link accordingly.

Cisco ASA documentation

Cisco FTD message 748002

Severity 4 — Warning

Message format

%FTD-4-748002: Clustering configuration on the chassis is missing or incomplete;

Explanation

Configurations are missing or incomplete in the MIO (for example, a cluster group is not configured, or a cluster control link is not configured). • slot_number —The blade slot ID within the chassis • chassis_number —The chassis ID, which is unique for each chassis

Recommended action

Go to the MIO console and configure the cluster service type, add the module to the service type, and define the cluster control link accordingly.

Cisco FTD documentation

← Previous: 748001Next: 748003 →

Search another message · Browse this range

Dataset generated May 29, 2026. Site content cleanup October 4, 2026; this is not a new Cisco documentation release.