Cisco ASA Syslog 776001: CTS SXP: Configured source IP source ip error.\n
Reference for ASA firewall logs. Check the source documentation against your installed software version.
Cisco ASA message 776001
Severity 3 — Error
Message format
%ASA-3-776001: CTS SXP: Configured source IP source ip error.\nExplanation
An error occurred while using this configured source IP address to set up an SXP connection. • source ip —IPv4 or IPv6 source address • error —Detailed message regarding what type of error occurs while using the configured address to set up the SXP connection, which can be one of the following: - Does not belong to this device. - Does not match outbound interface IP address.
Plain-English interpretation
The ASA failed to establish an SXP (Scalable Group Tag eXchange Protocol) connection using the configured source IP because that IP either doesn't exist on the device or doesn't match any outbound interface address. This typically occurs when the source IP is manually specified but doesn't correspond to an actual interface IP or when the interface configuration has changed since the SXP source was configured.
Recommended action
Reconfigure the SXP connection to have a valid source IP address. Alternatively, unconfigure the source IP address and let the device select the correct source IP address based on a route lookup.
Illustrative example
Illustration; not a captured production log.
%ASA-3-776001: CTS SXP: Configured source IP 10.50.1.254 error. Does not belong to this device.The ASA attempted to use 10.50.1.254 as the source IP for an SXP connection but failed because that IP address is not configured on any interface of this device, preventing the SXP session from being established.